Sizing & planning
Size a hood in five minutes.
Answer a few questions about your cooktop and your room. The guide applies published rules of thumb and tells you which rule sets each number.
Airflow
600CFM minimum
Hood width
36in or wider
Mounting height
30–36in above the cooktop
Duct
7–8in round duct (typical)
Above 400 CFM, the International Residential Code can require makeup air, depending on the code edition and local amendments where you live. Check with your building department before you buy.
Ceiling height of 10 ft: a wall or island hood may need a chimney extension to reach it.
General guidance based on published rules of thumb. It does not replace the installation instructions for your hood and cooktop or the building code where you live.
The guide
Where the numbers come from.
Eight things that decide how well a hood works once it is on the wall.
Airflow
Airflow is measured in cubic feet per minute, or CFM. The Home Ventilating Institute suggests at least 100 CFM for every linear foot of cooktop width on a wall, and 150 CFM per foot over an island. For gas, a second rule applies: 1 CFM for every 100 BTU of combined burner output.
A 30-inch electric cooktop on a wall works out to 250 CFM. A 36-inch gas range with 60,000 BTU of burners works out to 600 CFM. Use whichever rule gives the higher number, then resist going far beyond it. More airflow means more noise and can trigger makeup air requirements.
Width and overhang
A hood should be at least as wide as the cooking surface. Over an island, add about 3 inches on each side, because air reaches the plume from every direction. With high-output burners, a griddle, or a lot of high-heat cooking, a hood one size wider than the cooktop helps.
Depth
The canopy should reach far enough forward to cover the front burners. That is where most cooking happens, and a shallow hood lets the plume roll out past its front edge.
Mounting height
Height is a trade-off. A lower hood captures more; a higher hood is easier to work under. Many manufacturers specify 24 to 30 inches above electric and induction cooktops and 30 to 36 inches above gas. The installation instructions for your hood are the final word.
Ductwork
When a hood is ducted, the International Residential Code, which most U.S. homes follow, calls for smooth-walled metal duct of galvanized steel, stainless steel, or copper, a backdraft damper, and a run that ends outdoors, never in an attic or crawl space.
Keep the run short and straight, use the duct size the hood is designed for, and never reduce it. Every elbow adds resistance.
Ducted or recirculating
A recirculating hood pulls air through grease filters and charcoal filters and returns it to the kitchen. It removes some odor and grease, but not heat or moisture, and the charcoal filters need regular replacement. Where a duct to the outside is possible, it is the better choice.
Makeup air
Every cubic foot of air a hood pushes outside has to be replaced by air coming in from somewhere. Under the International Residential Code, hoods that can exhaust more than 400 CFM may need a makeup air system, depending on the code edition your area has adopted and its local amendments. Ask your building department before choosing a high-airflow hood.
Noise
Hood noise is rated in sones, a measure of how loud a sound seems to a listener. Lower is quieter, and one sone is often compared to the hum of a quiet refrigerator. Ratings are usually published for several speeds, so compare them at the speed you expect to use most.

Before the installer arrives
A checklist for the installation.
Gather these answers before the hood is ordered. Most installation surprises come from one of them.
- Cooktop or range model, width, and fuel
- Combined burner output in BTU, for gas
- Ceiling height, plus any soffits or beams in the way
- Duct route and where it leaves the house: wall cap or roof cap
- Duct diameter required by the hood
- Blocking in the wall or ceiling to carry the hood's weight
- Electrical supply as specified in the installation instructions
- Makeup air requirement confirmed with the building department
- Mounting height from the cooktop to the bottom of the hood
- Access to filters and lights once the kitchen is finished
Want a second opinion on your numbers?
Send us what the guide gave you, along with the duct route. We will tell you if anything looks off.
contact@pioneerkitchenvent.com